Architectural Flashing Supply
Start a Quote
Material data sheets

Material Data Sheets

64 documents AFS has on file today: certifications, tested ratings, method sheets, standards and data. Add any of them to a submittal package.

Certification

1 ON FILE

Drexel Metals ES-1/GT-1 Certification Program

Drexel Metals
Conditions and limits (4)
  • Applies only to Drexel Metals ES-1 rated perimeter edge systems and GT-1 rated gutter systems.
  • Authorized after a third-party quality-control audit, per shop location; certification is good for one year.
  • All material must be purchased through Drexel Metals: painted sheets for cover and splice, galvanized sheets for cleats, and fasteners/nails. Cleats are pre-punched with properly spaced holes and secured with Drexel-provided fasteners.
  • AFS is not tested or certified for GT-1 gutters.

Tested systems (ES-1)

9 ON FILE

Only the Drexel Metals ES-1 systems listed here, fabricated by AFS under the Drexel certification program from Drexel-supplied material, carry Drexel's published ES-1 ratings. A non-Drexel or custom fabricated AFS component does not carry that tested rating, or the tested performance of any independently tested proprietary assembly.

Drexel Metals Snap Coping-Max

Drexel Metals
Published ratings (2)
  • 24 gauge cover, face up to 12 in, wall up to 32 in: -75 psf sustained (Drexel published test value)
  • .040 AL cover, face up to 12 in, wall up to 32 in: -75 psf sustained (Drexel published test value)
  • Design Engineer must apply the Factor of Safety.
  • Applies only to Drexel Metals ES-1 rated perimeter edge systems and GT-1 rated gutter systems.
  • Authorized after a third-party quality-control audit, per shop location; certification is good for one year.
  • All material must be purchased through Drexel Metals: painted sheets for cover and splice, galvanized sheets for cleats, and fasteners/nails. Cleats are pre-punched with properly spaced holes and secured with Drexel-provided fasteners.
  • Applies only to the Snap Coping-Max as published by Drexel. A non-Drexel or custom profile does not carry this rating.

Drexel Metals Snap Coping-Max-C

Drexel Metals
Published ratings (3)
  • 24 gauge cover, face up to 12 in, wall up to 24 in: -170 psf sustained (Drexel published test value)
  • .040 AL cover, face up to 12 in, wall up to 24 in: -180 psf sustained (Drexel published test value)
  • .050 AL cover, face up to 12 in, wall up to 32 in: -155 psf sustained (Drexel published test value)
  • Design Engineer must apply the Factor of Safety.
  • Applies only to Drexel Metals ES-1 rated perimeter edge systems and GT-1 rated gutter systems.
  • Authorized after a third-party quality-control audit, per shop location; certification is good for one year.
  • All material must be purchased through Drexel Metals: painted sheets for cover and splice, galvanized sheets for cleats, and fasteners/nails. Cleats are pre-punched with properly spaced holes and secured with Drexel-provided fasteners.
  • Applies only to the Snap Coping-Max-C as published by Drexel. A non-Drexel or custom profile does not carry this rating.

Drexel Metals Econo Coping LT

Drexel Metals
Published ratings (4)
  • 24 gauge cover, face up to 6 in, wall up to 16 in, 24 ga cleat: -110 psf sustained (Drexel published test value)
  • 24 gauge cover, face up to 6 in, wall up to 20 in, 24 ga cleat: -85 psf sustained (Drexel published test value)
  • .040 AL cover, face up to 6 in, wall up to 16 in, 24 ga cleat: -115 psf sustained (Drexel published test value)
  • .040 AL cover, face up to 6 in, wall up to 20 in, 24 ga cleat: -85 psf sustained (Drexel published test value)
  • Design Engineer must apply the Factor of Safety.
  • Applies only to Drexel Metals ES-1 rated perimeter edge systems and GT-1 rated gutter systems.
  • Authorized after a third-party quality-control audit, per shop location; certification is good for one year.
  • All material must be purchased through Drexel Metals: painted sheets for cover and splice, galvanized sheets for cleats, and fasteners/nails. Cleats are pre-punched with properly spaced holes and secured with Drexel-provided fasteners.
  • Applies only to the Econo Coping LT as published by Drexel. A non-Drexel or custom profile does not carry this rating.

Drexel Metals Econo Coping

Drexel Metals
Published ratings (4)
  • 24 gauge cover, face up to 6 in, wall up to 16 in, 22 ga cleat: -110 psf sustained (Drexel published test value)
  • 24 gauge cover, face up to 6 in, wall up to 20 in, 22 ga cleat: -75 psf sustained (Drexel published test value)
  • .040 AL cover, face up to 6 in, wall up to 16 in, 22 ga cleat: -145 psf sustained (Drexel published test value)
  • .040 AL cover, face up to 6 in, wall up to 20 in, 22 ga cleat: -65 psf sustained (Drexel published test value)
  • Design Engineer must apply the Factor of Safety.
  • Applies only to Drexel Metals ES-1 rated perimeter edge systems and GT-1 rated gutter systems.
  • Authorized after a third-party quality-control audit, per shop location; certification is good for one year.
  • All material must be purchased through Drexel Metals: painted sheets for cover and splice, galvanized sheets for cleats, and fasteners/nails. Cleats are pre-punched with properly spaced holes and secured with Drexel-provided fasteners.
  • Applies only to the Econo Coping as published by Drexel. A non-Drexel or custom profile does not carry this rating.

Drexel Metals Fascia LT

Drexel Metals
Published ratings (2)
  • 24 gauge cover, face up to 8 in, 22 ga cleat: -210 psf sustained (Drexel published test value)
  • .040 AL cover, face up to 6 in, 22 ga cleat: -180 psf sustained (Drexel published test value)
  • Design Engineer must apply the Factor of Safety.
  • Applies only to Drexel Metals ES-1 rated perimeter edge systems and GT-1 rated gutter systems.
  • Authorized after a third-party quality-control audit, per shop location; certification is good for one year.
  • All material must be purchased through Drexel Metals: painted sheets for cover and splice, galvanized sheets for cleats, and fasteners/nails. Cleats are pre-punched with properly spaced holes and secured with Drexel-provided fasteners.
  • Applies only to the Fascia LT as published by Drexel. A non-Drexel or custom profile does not carry this rating.

Drexel Metals Gravel Stop

Drexel Metals
Published ratings (2)
  • 24 gauge cover, face up to 10 in, 22 ga cleat: -140 psf sustained (Drexel published test value)
  • .040 AL cover, face up to 10 in, 22 ga cleat: -130 psf sustained (Drexel published test value)
  • Design Engineer must apply the Factor of Safety.
  • Applies only to Drexel Metals ES-1 rated perimeter edge systems and GT-1 rated gutter systems.
  • Authorized after a third-party quality-control audit, per shop location; certification is good for one year.
  • All material must be purchased through Drexel Metals: painted sheets for cover and splice, galvanized sheets for cleats, and fasteners/nails. Cleats are pre-punched with properly spaced holes and secured with Drexel-provided fasteners.
  • Applies only to the Gravel Stop as published by Drexel. A non-Drexel or custom profile does not carry this rating.

Drexel Metals Econo Gravel Stop

Drexel Metals
Published ratings (2)
  • 24 gauge cover, face up to 7 in, 24 ga cleat: -70 psf sustained (Drexel published test value)
  • .040 AL cover, face up to 7 in, 24 ga cleat: -90 psf sustained (Drexel published test value)
  • Design Engineer must apply the Factor of Safety.
  • Applies only to Drexel Metals ES-1 rated perimeter edge systems and GT-1 rated gutter systems.
  • Authorized after a third-party quality-control audit, per shop location; certification is good for one year.
  • All material must be purchased through Drexel Metals: painted sheets for cover and splice, galvanized sheets for cleats, and fasteners/nails. Cleats are pre-punched with properly spaced holes and secured with Drexel-provided fasteners.
  • Applies only to the Econo Gravel Stop as published by Drexel. A non-Drexel or custom profile does not carry this rating.

Drexel Metals Drip Edge LT

Drexel Metals
Published ratings (2)
  • 24 gauge cover, face up to 6 in, 24 ga cleat: -240 psf sustained (Drexel published test value)
  • .040 AL cover, face up to 6 in, 24 ga cleat: -250 psf sustained (Drexel published test value)
  • Design Engineer must apply the Factor of Safety.
  • Applies only to Drexel Metals ES-1 rated perimeter edge systems and GT-1 rated gutter systems.
  • Authorized after a third-party quality-control audit, per shop location; certification is good for one year.
  • All material must be purchased through Drexel Metals: painted sheets for cover and splice, galvanized sheets for cleats, and fasteners/nails. Cleats are pre-punched with properly spaced holes and secured with Drexel-provided fasteners.
  • Applies only to the Drip Edge LT as published by Drexel. A non-Drexel or custom profile does not carry this rating.

Drexel Metals Drip Edge

Drexel Metals
Published ratings (2)
  • 24 gauge cover, face up to 6 in, 22 ga cleat: -175 psf sustained (Drexel published test value)
  • .040 AL cover, face up to 6 in, 22 ga cleat: -185 psf sustained (Drexel published test value)
  • Design Engineer must apply the Factor of Safety.
  • Applies only to Drexel Metals ES-1 rated perimeter edge systems and GT-1 rated gutter systems.
  • Authorized after a third-party quality-control audit, per shop location; certification is good for one year.
  • All material must be purchased through Drexel Metals: painted sheets for cover and splice, galvanized sheets for cleats, and fasteners/nails. Cleats are pre-punched with properly spaced holes and secured with Drexel-provided fasteners.
  • Applies only to the Drip Edge as published by Drexel. A non-Drexel or custom profile does not carry this rating.

Method sheets

15 ON FILE

Standards

5 ON FILE

Codes

7 ON FILE

Material data

10 ON FILE

Finish data

3 ON FILE

Climate data

2 ON FILE

Derivations

9 ON FILE

Right-triangle geometry (Pythagorean theorem and trigonometric ratios)

Method sheets roof-geometry/1.0 and geometry-conversion/1.0

AFS shop data

3 ON FILE

Need something that isn't listed?

Ask AFS for mill certificates, warranty terms or a project-specific document. We reply by email.