Architectural Flashing Supply
Start a Quote
Method sheet

Geometry, Slope & Unit Conversion

Exact unit conversion (length, area, volume, mass, temperature); right triangle from any two values; slope as x:12, 1:x, percent and degrees; ramp running slope against 1:12; tolerance stack-up by worst case and RSS.

Method

geometry-conversion 1.1

Engine

1.1.0

Output status

Informational

Review

Awaiting review

Formulas

  • Exact factors: 1 in = 25.4 mm, 1 ft = 0.3048 m, 1 lb = 0.45359237 kg, 1 U.S. gal = 231 in3; areas and volumes as squares and cubes
  • Right triangle: c^2 = a^2 + b^2; a = c sin A; b = c cos A; A + B = 90 deg
  • Slope = rise / run; percent = 100 x rise / run; degrees = atan(rise / run)
  • Ramp: running slope compared with 1:12 (2010 ADA Standards 405.2)
  • Worst case = sum of tolerances; RSS = sqrt(sum of squared tolerances)

Conventions

  • Angle A is opposite leg a; the right angle is between the legs.
  • Tolerances are symmetric (+/-).

Limits - what it will not do

  • The ramp check is a reference check of 405.2 only - not a code compliance determination. Cross slope, landings, rise limits, handrails and local codes are not checked.
  • RSS assumes independent, centred, normally distributed dimensions.

Who must review it

  • AFS: confirm the units and tolerances the shop and its customers use

Worked example

Inputs 12 ft to m; legs 3 and 4; 1:12 slope; dimensions 10 +/- 0.1, 20 +/- 0.2, 5 +/- 0.05

Expected 3.6576 m; hypotenuse 5, 36.87 / 53.13 deg; 8.33%, 4.76 deg; 35 +/- 0.35 worst case, +/- 0.229 RSS

Checked by an automated test on every change.

Sources

  • NIST Special Publication 811 - Guide for the Use of the International System of Units (SI), Appendix B conversion factors - National Institute of Standards and Technology, read 2026-10-16

    Exact factors: 1 in = 0.0254 m; 1 ft = 0.3048 m; 1 yd = 0.9144 m; 1 mi = 1609.344 m; 1 lb = 0.45359237 kg; 1 U.S. gallon = 231 in3 = 3.785411784 L; 1 Btu (IT) = 1055.05585262 J; t(degC) = (t(degF) - 32) / 1.8; T(K) = t(degC) + 273.15.

  • Right-triangle geometry (Pythagorean theorem and trigonometric ratios) - Method sheets roof-geometry/1.0 and geometry-conversion/1.0, read 2026-10-16

    Slope factor = sqrt(1 + (rise/run)^2); a hip or valley between equal-pitch planes meeting at 90 deg in plan runs sqrt(2) x the common run, so its length factor is sqrt(2 + (rise/12)^2) per unit of common run.

  • 2010 ADA Standards for Accessible Design, 405.2 Slope - U.S. Department of Justice, read 2026-10-16

    Ramp runs shall have a running slope not steeper than 1:12. Used here as a reference check of one provision only, not a code compliance determination.

  • Linear tolerance stack-up: worst case and root sum of squares - Method sheet geometry-conversion/1.0, read 2026-10-16

    Worst case = sum of the tolerances; RSS = square root of the sum of the squared tolerances, valid for independent, centred, normally distributed dimensions.