Coping Cap - Both Edges Open
The FlashDraft section for this condition, in 3D and as a lettered section.
Legs
| Leg | Length |
|---|---|
| B | Drawn to proportion - set it in FlashDraft |
| C | Drawn to proportion - set it in FlashDraft |
| D | Drawn to proportion - set it in FlashDraft |
| E | Drawn to proportion - set it in FlashDraft |
| F | Drawn to proportion - set it in FlashDraft |
This section has a hem. The DXF draws it on its own layer; Open in FlashDraft carries it with the section.
Related calculators
- Flashing Profile & Bend Development - Legs, bends and hems to a blank width, bend schedule, weight and an AFS fabrication check.
- Roof Edge, Coping & Fascia - Edge runs, corners and terminations to pieces, joints, end caps and cleat length.
- Thermal Movement & Compatibility - Expansion and contraction of a run between metal temperature extremes, and dissimilar-metal screening.
- Wind Uplift & Edge Screening - ASCE 7-16 edge pressures for comparison with ES-1 tested capacity. Preliminary.
Drexel ES-1 systems with this section
Snap Coping-Max
16 Ga Galv. Intermittent Cleat, Snap-On Cover
Published sustained pressure: 24 gauge -75 psf (face to 12", wall to 32"); .040 AL -75 psf (face to 12", wall to 32")
Snap Coping-Max installation sequenceSnap Coping-Max-C
16 Ga Galv. Segmented Cleat w/Spring Clip, Snap-On Cover
Published sustained pressure: 24 gauge -170 psf (face to 12", wall to 24"); .040 AL -180 psf (face to 12", wall to 24"); .050 AL -155 psf (face to 12", wall to 32")
Snap Coping-Max-C installation sequenceEcono Coping LT
24 Gauge Formed Cont Cleat; (Front Face) Exposed Fastener; (Back Face) Drip Profile
Published sustained pressure: 24 gauge -110 psf (face to 6", wall to 16"); 24 gauge -85 psf (face to 6", wall to 20"); .040 AL -115 psf (face to 6", wall to 16"); .040 AL -85 psf (face to 6", wall to 20")
Econo Coping LT installation sequenceEcono Coping
22 Gauge Formed Cont Cleat; (Front Face) Exposed Fastener; (Back Face) Drip Profile
Published sustained pressure: 24 gauge -110 psf (face to 6", wall to 16"); 24 gauge -75 psf (face to 6", wall to 20"); .040 AL -145 psf (face to 6", wall to 16"); .040 AL -65 psf (face to 6", wall to 20")
Econo Coping installation sequence- Ratings as Drexel Metals publishes them for its own tested assemblies, not for a drawing made here. Design Engineer must apply the Factor of Safety.