Defects at the sill
BSC says a pan's function can be subverted if the collected water cannot drain to the exterior, for example when the window's bottom flange is sealed to the drainage plane.
DuPont says sill flashing must not slope to the interior.
A pan with no back dam or slope, or no end dams, lets water run to the interior or off the sides into the wall.
Three pairs, correct on the left and incorrect on the right: a pan with end dams against a flat strip, an open bottom flange against one sealed solid, and a folded dog ear corner against a cut corner closed with sealant.
- A
- Pan with end dams: water stays on the pan
- B
- Flat strip with no end dams: water runs off the end
- C
- Bottom flange left open: the pan drains
- D
- Bottom flange sealed solid: the water is trapped
- E
- Flat folded dog ear at the pan corner
- F
- Corner cut and closed only with sealant