Inspect the substrate first
Check before the cover goes on, against the drawings and the guide:
- Wood sound, no rot or splits
- Thickness, height and width
- Fasteners per member, end distance, spacing
- Anchorage to the engineer's design
- Fastener metal, isolation, cleat height
- The printed pattern, corners closer
A checklist card of twelve numbered rows with a short label each: sound wood, thickness, flush height, width, fasteners per member, stacked spacing, anchorage, fastener metal, isolation, cleat height, printed pattern, coverage over the wall. Below it, the fields of an evidence log.
- 1
- Wood sound: no rot, no splits (proposed ED-1)
- 2
- Each layer at least 1.5 in thick (proposed ED-1)
- 3
- Top flush with the insulation (Carlisle: flush with the membrane underlayment; built to the detail)
- 4
- Width at least flange + 1/2 in (proposed ED-1)
- 5
- Each member: at least 2 fasteners, about 4 in and not less than 3 in from the ends (proposed ED-1 commentary)
- 6
- Stacked members: at most 12 in on center, 6 in in corners (proposed ED-1 commentary)
- 7
- Anchorage to the engineer's design; drawing reference recorded
- 8
- Fastener metal suits the wood treatment (the adopted code, NRCA)
- 9
- Metal isolated from treated wood, or galvanically compatible with it (proposed ED-1); Drexel's note 1 requires a membrane
- 10
- Cleat at the detail height (2024 Wall of Wind tests)
- 11
- The maker's printed fastener and spacing, closer at corners
- 12
- Coverage at least 1 in over the wall face (proposed ED-1)