Architectural Flashing Supply
Start a Quote
Jobsite readiness and hazard controls · Lesson 2 of 4

Jobsite readiness and hazard controls: materials, standards and design constraints

The numbers inside each control: guardrail heights and loads, warning line distances and build, safety monitor rules, cover ratings, fall arrest limits, ladder set-up, metal near power lines, heat and weather.

You will be able to: Identify the numeric criteria for guardrails, warning lines, safety monitors, covers, fall arrest and ladders, and the constraints set by roof slope, roof width, power lines, heat and weather.

21 min · 12 slides · 21 questions

All lessons in this module
Slide 1 of 12

Guardrails and toeboards

The top edge of a guardrail is 42 in, plus or minus 3 in, above the walking/working level.

The top rail withstands at least 200 lb applied within 2 in of its top edge, in any outward or downward direction.

Where no wall or parapet at least 21 in high stands below the top rail, midrails, screens or similar members go in; midrails sit midway.

Toeboards are at least 3-1/2 in high.

Guardrail heights and loadsSection through a guardrail near a roof edge, the drop on the right: a post, a top rail 42 in plus or minus 3 in above the roof surface, a midrail halfway down, and a toeboard at least 3-1/2 in high on the edge side. Two arrows at the top rail mark the 200 lb test load within 2 in of the top edge: one pushing down, one pushing outward toward the edge.42 in± 3 in200 lb, downor outwardGuardrail at a roof edge, sectionwithin 2 inof the top edgeedge, dropto lower levelNot to scaleABCDE

A guardrail near a roof edge, in section: top rail 42 in plus or minus 3 in above the surface, a midrail midway, a toeboard at least 3-1/2 in high on the edge side and a post. Two arrows at the top rail mark the 200 lb load within 2 in of the top edge, one downward and one outward toward the edge.

A
Top rail: 42 in, plus or minus 3 in, above the walking/working level
B
Midrail, midway between the top rail and the surface
C
Toeboard, at least 3-1/2 in high
D
Post
E
Test load: at least 200 lb within 2 in of the top edge, in any outward or downward direction (1926.502(b)(3))
Criteria from 29 CFR 1926.502(b) and (j). Midrails are needed where no wall or parapet at least 21 in high is below the top rail. Not to scale.

Videos for this lesson

What this video shows: OSHA prevention video. Framers on a second floor step into an unguarded stairwell opening and fall 20 ft; the replay adds a guardrail and a secured cover. Framing, not roofing, but the same hole rules. Checked against OSHA's published transcript.

Video: Falls in Construction/Floor Openings by USDepartmentofLabor, on YouTube. AFS checked its transcript against this lesson.

Glossary

Warning line system
A barrier on a roof that warns employees they are approaching an unprotected roof side or edge.
Safety-monitoring system
A system in which a competent person is responsible for recognizing and warning employees of fall hazards.
Mechanical equipment
Motor or human-propelled wheeled equipment used for roofing work, except wheelbarrows and mopcarts.
Toeboard
A low barrier that stops materials and equipment falling to lower levels; at least 3-1/2 in high.
General Duty Clause
Section 5(a)(1) of the OSH Act: a workplace free from recognized hazards likely to cause death or serious harm. OSHA uses it for heat.