Two layers at one joint
Where a roof meets a wall, base flashing turns up the wall from the roof and counterflashing comes down from the wall above and laps over it.
Hodgin describes counterflashing as a second (upper) layer of protection that keeps water from getting behind the lower layer.
Section through a low-slope roof meeting a masonry wall: the membrane base flashing runs up the wall to a termination bar, and a counterflashing set in a reglet in a mortar joint comes down over it with its hemmed lower edge kept clear of the roof. Water running down the wall lands on the counterflashing and then on the base flashing.
- A
- Roof deck
- B
- Insulation and cover board
- C
- Field membrane
- D
- Membrane base flashing up the wall
- E
- Termination bar and fastener
- F
- Reglet cut in a mortar joint
- G
- Lead wedge at the back of the reglet
- H
- Mortar or sealant fill, per specification
- J
- Counterflashing (AFS metal) with a rounded hem at the lower edge
- K
- Lap of counterflashing over base flashing
- L
- Clearance between the bottom edge and the roof