Edge metal and the building code
Section 1504.6 of the 2021 International Building Code, as SPRI quotes it, covers metal edge systems, except gutters and counterflashing, on built-up, modified bitumen and single-ply roofs with a slope under 2:12.
They must be designed for Chapter 16 wind loads and tested for resistance to Test Methods RE-1, RE-2 and RE-3 of ANSI/SPRI ES-1.