CAD detail standards and coordination · Lesson 4 of 4

CAD detail standards and coordination: defects, verification and case study

Eight common detail defects with corrections, a review checklist, the case where a 36 in wall height was read as a coping leg, and what to send with a packet.

You will be able to: Diagnose a drawing or coordination defect, state the corrective options, and document the evidence for review, including the wall-height case.

10 min · 11 slides · 6 questions

All lessons in this module
Slide 1 of 11

Eight defects to look for

Eight defects to look for in flashing details: a butted coping, a cleat fixed tight, an untested substitute, a gauge without a metal, a dimension on the wrong element, an unrecorded unit, a drawing that disagrees with the specification, and a control layer that stops at the parapet.

Glossary

Termination metal
Metal at the top of wall flashing that closes the joint between the wall and the coping. A trade article calls leaving it out and butting the coping to the wall the most common coping mistake.
Attribution
In AFS's CAD reader, tying each dimension and note to the drawn element it measures or describes, so a number is never read as belonging to the wrong part.
Control layers
The water, air, vapor and thermal control layers of a roof and wall. Building Science Corporation says those of the roof connect to the wall's at a parapet.
Synthetic test drawing
A made-up test drawing, built to reproduce a defect. AFS's wall-height case comes from one, not from a customer's drawing.