Thermal bridging and energy performance · Lesson 4 of 4

Thermal bridging and energy performance: defects, verification and case study

Where flashing meets the thermal layer, four design defects with their catalogue evidence, a worked case study of metal against membrane flashing at a thermally broken shelf angle, and the record a design team keeps.

You will be able to: Diagnose the common ways sheet-metal flashing defeats the thermal layer, explain the corrective options that belong to the designer of record, and list the evidence a design team keeps.

12 min · 11 slides · 8 questions

All lessons in this module
Slide 1 of 11

Where sheet metal meets the thermal layer

One question for every flashing detail: does any leg cross the insulation or a thermal break?

Five places to ask it: the parapet and coping, a shelf angle, window head flashing, window sill flashing, and floor-line flashing that bypasses exterior insulation.

BC Hydro's catalogue pairs wood-frame rim joist details 8.2.1 and 8.2.2, with and without metal flashing bypassing exterior insulation.

Sources

Glossary

Flashing at a thermally broken shelf angle
BC Hydro's detail 5.2.29 models a thermally broken steel shelf angle with metal flashing and with self-adhered membrane flashing, giving psi 0.41 and 0.234 W/(m·K) at R-15 exterior insulation.
Glazing transition
BC Hydro's name for the interface where wall assemblies meet glazing; its categories run from Efficient (0.2 W/(m·K)) to Poor (0.5), depending on insulation alignment and whether flashing bypasses the glazing thermal break.
Coping (as BC Hydro models it)
In BC Hydro's parapet data sheets 5.5.10 and 5.5.11, cap flashing is folded into the exterior heat transfer coefficient rather than modelled as a separate conductor.