Flashing geometry and movement accommodation
How an architect or specifier gives flashing room to move: choosing the design temperature range, the fixed point and the joint family, working the movement, checking the geometry against AFS fabrication limits, and reviewing the drawings for defects.
4 lessons · about 45 min · 13 diagrams · 3 videos
Version 1.0.0
Builds on these modules
Related Academy lessons
Lessons
0 of 4 complete
Lesson 1 · 12 min · 12 slides · 9 questions
Flashing geometry and movement accommodation: principles and terminology
What makes a flashing run move, which decisions the drawings make about it, where a run is held, what restrains it and how lengths are joined, with the roof safety rule that applies on a site visit.
You will be able to: Define design temperature range, fixed point, sliding clip, restraint and the main ways lengths are joined, and name the decisions in the drawings that give a flashing run room to move.
Not startedStart →Lesson 2 · 10 min · 11 slides · 7 questions
Flashing geometry and movement accommodation: materials, standards and design constraints
How coefficients differ by metal and by source, why zinc needs a roll direction, how published design ranges and specifications differ, and what ED-1 says about thickness and cleats.
You will be able to: Compare published coefficients by metal, choose and record a design temperature range from published examples, and name the standards and specifications that set joint and thickness rules for roof edge metal.
Not startedStart →Lesson 3 · 12 min · 12 slides · 8 questions
Flashing geometry and movement accommodation: methods and worked application
A design sequence from temperature range to fabrication check, worked on a 40 ft aluminum run and on piece joints, with the AFS limits a movement detail must fit and the notes the installer needs.
You will be able to: Apply a documented design sequence to a run of flashing: state the range and fixed point, work the movement, share it across joints, check differing metals, and test the detail against AFS fabrication limits.
Not startedStart →Lesson 4 · 11 min · 12 slides · 8 questions
Flashing geometry and movement accommodation: defects, verification and case study
Defects that come from the drawings rather than the field, what the sources say about oil canning, a drawing review checklist, and a fictional case study rewritten from range to fabrication check.
You will be able to: Diagnose movement defects that start in the drawings, explain the corrective options, and record the calculation, the marked-up detail and the review for a run of flashing.
Not startedStart →
Practical task
Prepare a movement review for a straight run of roof edge metal on a drawing set you choose. State a design temperature range with its source, pick the fixed point, work the movement for your metal and run length, choose the joint family, and check the profile against AFS limits. Mark anything the documents leave open as a written question to the designer.
Hand in
- The movement calculation with every input labelled as an example or sourced, the coefficient source named and the zinc roll direction stated if zinc is used
- A marked-up sketch of the run showing the fixed point, each joint, the joint family at each and the joint travel the detail must allow
- The completed drawing review checklist for the run, with each item marked and any failure explained
- A list of open questions for the designer, written as questions and not settled with an invented figure
Rubric
| Criterion | Meets the standard when |
|---|---|
| Range | The design range is stated as a metal surface range and its source is named, with no air temperature used in its place. |
| Movement | Movement is worked each side of the installation temperature with a named coefficient source, and the result is shown for the anchor chosen. |
| Fixed point | One fixed point is marked for each continuous piece (the length between movement joints) and no detail holds both ends of a piece. |
| Joints | Each joint is a lap, or a gap with a splice plate, and the travel it must take is stated from the calculation. |
| Fit | The profile is checked against the AFS limits for piece length, flat width, end flange, segment between bends and hem return, and anything outside them is flagged for AFS. |