Defects to look for
Most thickness and weight errors come from one of these:
- The wrong table for the material
- Stock thinner or thicker than its tag
- A gauge number on an aluminum order
- A thickness with no unit
- A weight with no stated basis
- Heavy steel on a profile it cannot take
Five pairs. Write 24 ga galvanized with 0.0276 in, not 24 ga alone. Use 1.156 lb for the galvanized piece weight, not the uncoated 1.000 lb. Order aluminum as 0.040 in, not 24 ga aluminum. Write 0.7 mm with its unit. Take three readings and check each against the band, not one reading.