Detail Atlas · Box Gutters
F Style Box Gutter - 5 in
The FlashDraft section for this condition, in 3D and as a lettered section.
Show
Loading 3D view…
Legs
| Leg | Length |
|---|---|
| A | 4-3/4" |
| B | 3" |
| C | 3-1/8" |
| D | 1-1/8" |
| E | 7/8" |
| F | Drawn to proportion - set it in FlashDraft |
| G | 1/2" |
Related calculators
- Flashing Profile & Bend Development - Legs, bends and hems to a blank width, bend schedule, weight and an AFS fabrication check.
- Material Takeoff & Nesting - Pieces into 10 ft strips and 48 in sheets, utilization and weight, ready to send to AFS.
- Thermal Movement & Compatibility - Expansion and contraction of a run between metal temperature extremes, and dissimilar-metal screening.
- Roof Drainage Flow Screening - Design flow from area and a sourced rainfall intensity, per outlet. Preliminary.
Drexel ES-1 systems with this section
No Drexel ES-1 system AFS fabricates uses this section. Ask AFS about tested assemblies for this condition.