The sequence, step by step
The course sequence: intake and history, survey and photographs, locate the roof point, list candidates with disproving tests, non-destructive checks, one-component water checks, exploratory opening, confirm, correct, retest, report.
The figure tags steps from a cited document and marks the rest as the method taught here. ASTM E2128 is a wall guide, used here by analogy.
Flow chart: intake and history; condition survey and photographs; locate the roof point from the interior symptom; list candidates with a disproving test; non-destructive checks; a decision on whether the source is outside the wall or roof system or is condensation; one-component water check where a method exists; exploratory opening; a decision on whether the cause is shown by evidence, looping back to the candidate list if not; correct with the warranty first; retest; report with limits.
Sources
- UFC 3-110-03 Roofing (1 May 2012, Change 5, 12 June 2020), sections 7-3 and 7-6 to 7-7 - U.S. Department of Defense, published by the Whole Building Design Guide
- ASTM E2128-26 Standard Guide for Evaluating Water Leakage of Building Walls (store page, scope only) - ASTM International
- ASTM E1188-23 Standard Practice for Collection and Preservation of Information and Physical Items by a Technical Investigator (store page, scope only) - ASTM International