From rainfall to the shop
The order of work: rainfall for the site, the area draining to each outlet, the flow, the downspout and gutter sizes, then the FlashDraft profile, the AFS limits check, forming and inspection.
The first steps belong to the designer. The shop checks that the drawing it receives adds up and can be made.
A flow of eight numbered steps from the rainfall for the site to inspection and shipping, split into the designer's steps and the shop's steps, with a side note that overflow drainage is sized by the designer to the adopted code.
- 1
- Rainfall for the site (NOAA Atlas 14)
- 2
- Area to each outlet: plan area x CDA pitch factor
- 3
- Flow: Q = 0.0103896 x A x I (Design Center)
- 4
- Downspout and gutter sizes (CDA method, by the designer)
- 5
- FlashDraft profile from the approved drawing
- 6
- AFS limits: girth up to 48 in, piece up to 126 in, metal and bends
- 7
- Formed on AFS's Thalmann folder
- 8
- Inspect, record and ship
Sources
- Design Center roof drainage flow screening method - Architectural Flashing Supply
- NOAA Atlas 14 Precipitation Frequency Data Server - NOAA National Weather Service
- AFS fabrication limits - materials, thicknesses, bend rules and sizes the shop can make - Architectural Flashing Supply
- FlashDraft to the AFS Thalmann folder (via PathfinderEdge): legs, bend angles and blank width; painted side and 3D confirmation - Architectural Flashing Supply