Inspect before it ships
Check each piece against the order and the print approval, never from memory:
- Material, painted side and decimal thickness
- Top width, each leg and the girth
- Hems, kicks and drips as drawn
- Face flat along a straightedge
- Length and square ends
- Cleats, splice plates, miters, end caps and paperwork
A formed red coping in section, its painted face a blue line, with lettered checks: painted face, thickness, top width, face leg, hems, drips and face flatness against a dashed straightedge. Below, the flat blank for the girth, then a cleat, a splice plate, a packing label and a length of cover, each lettered.
- A
- Material and painted side as ordered (painted face: the blue line)
- B
- Thickness in decimals, against the order
- C
- Top width: the wall plus the allowance
- D
- Each face leg, to the mold line
- E
- Girth: legs and hem allowances add up to the flat blank
- F
- Hems: right end and face, return at least 0.375 in, rounded
- G
- Kicks and drips as drawn
- H
- Face flat along a straightedge (no tolerance number is on record)
- I
- Length and square ends
- J
- Cleat gauge and punching as the system specifies
- K
- Splice plates, miters and end caps counted against the length plan
- L
- Documentation packed: the ES-1 component documentation where it applies
Sources
- AFS fabrication limits - materials, thicknesses, bend rules and sizes the shop can make - Architectural Flashing Supply
- FlashDraft hem types and starting dimensions - Architectural Flashing Supply
- ES-1/GT-1 Certification Program Product Line Card, DM-19063 (12.09.25), AFS file copy - Drexel Metals
- ANSI/SPRI/FM 4435/ES-1-2022 Test Standard for Edge Systems Used with Low Slope Roofing Systems (approved November 21, 2022) - SPRI