Architectural Flashing Supply
Start a Quote
Base counterflashing and reglet fabrication · Lesson 4 of 4

Base counterflashing and reglet fabrication: defects, verification and case study

The recurring defects and which ones start in the shop, correct and incorrect details, sealant and fasteners, shop and field checks, and a case study from diagnosis to remake.

You will be able to: Tell shop defects from site defects in a regleted counterflashing, inspect a formed piece against the order, diagnose a flange that does not match the reglet and a short lap, and document the evidence and the fix.

10 min · 11 slides · 7 questions

All lessons in this module
Slide 1 of 11

Videos for this lesson

What this video shows: One contractor sets flat-roof wall flashings into a 3/4 in reglet already cut into the mortar with a grinder and diamond blade. That reglet is this contractor's choice, not a standard, and the cut makes silica dust.

Video: Flat Roof - How to Install Wall Flashings by Schoen Roofing, on YouTube. Chosen from the video's published description.

Glossary

Ledge
The part of a reglet flange that projects from the wall face when the flange is longer than the reglet is deep; Levine warns it can pond water or send it into the wall.
Hook dam
Levine: the hook at the back end of the reglet flange, which impedes stray moisture.
Exposed fastener
A fastener left visible through the face; Levine says a properly detailed counterflashing has none.
Defect record
What was found, the value and source it misses, the fix and the check that proved it.