Architectural Flashing Supply
Start a Quote
ANSI/SPRI/FM 4435/ES-1 edge systems · Lesson 1 of 4

ANSI/SPRI/FM 4435/ES-1 edge systems: principles and terminology

Why the roof perimeter matters, the cover and cleat, ES-1 as a test of a whole assembly, the SPRI standards timeline, the three test methods, the IBC edge-system rule, and the fall-protection boundary at an unprotected edge.

You will be able to: Name the parts of a cleated edge system, say what ES-1 tests and what it does not, place it among the SPRI edge standards, and say where the building code asks for it.

10 min · 10 slides · 6 questions

All lessons in this module
Slide 1 of 10

Glossary

Edge system
The metal at the perimeter of a low-slope roof, such as coping, fascia or gravel stop, with its cleat and fasteners, treated as one assembly.
Cleat
The anchor strip, fastened to the roof edge, that the edge metal cover hooks onto; it has its own gauge and is its own part.
Sustained pressure
Drexel's term for the published test value of an edge system, printed in psf; the design engineer applies the factor of safety.
RE-3
The ES-1 test method that loads a coping cap on its top and face at the same time, in a ratio of 1.73 vertical to 1.00 horizontal, per SPRI's description.
Authorized fabricator
A shop that Drexel has certified under its ES-1/GT-1 certification program to fabricate Drexel's tested systems. Drexel states the terms and can confirm a shop's status.