How edges fail in testing
NRCA's Mark Graham wrote in 2009 that flexural failure during testing is far more common than fastener failure.
NRCA later reported cleat deformation and disengagement from the hemmed edge of fascias and copings as a common failure mechanism in ES-1 testing.
The authors stress good engagement of the cleat with the drip edge.
Section through a parapet coping: a cover over the wall top whose front and back drip hems hook over the kickouts of a cleat fastened to each wall face, an amber ring around the front engagement zone, uplift and outward arrows, and a panel naming the Drexel Snap Coping-Max and Max-C systems with a segmented cleat; Econo Coping systems are not drawn.
- A
- Engagement zone where the cover drip hooks over the cleat kickout
- B
- Front face of the cover
- C
- Top of the cover
- D
- Back leg of the cover
- E
- Cleat on the wall face, with its kickout
Sources
- Understanding ANSI/SPRI ES-1 (Mark S. Graham, October 2009) - Professional Roofing (NRCA)
- Living on the edge (Grant, Kirby and Sherman, February 2024) - Professional Roofing (NRCA)