Coastal climate and exposure detailing · Lesson 4 of 4

Coastal climate and exposure detailing: defects, verification and case study

How to read a coastal defect, the common ones (rust at galvanized fasteners, sheltered undersides, copper run-off, edge lift), the safety boundary for inspection at height, a yearly inspection card, and a constructed case study.

You will be able to: Diagnose a plausible coastal corrosion defect from symptom to mechanism to evidence, explain corrective options as the designer's choice, and run the method on a constructed project.

10 min · 11 slides · 6 questions

All lessons in this module
Slide 1 of 11

Glossary

Mechanism
The reason a defect forms, such as salt accumulating on a surface rain does not reach. A defect note pairs the visible symptom with its mechanism, the evidence for it and the options to fix it.
Edge flashing blow-off
FEMA P-55 says roof membrane blow-off is typically caused by lifting and peeling of metal edge flashings (gravel stops) or copings, which clamp down the membrane at the roof edge.
Run-off staining
Damage to a metal surface from water that has run over another metal such as copper. The PAC-CLAD sample form excludes damage from run-off from lead, copper or other incompatible flashings.
Guardrail system
One of the fall protection systems OSHA lists in 1926.501(b) for work at 6 feet or more above lower levels, alongside safety net systems and personal fall arrest systems.