Defect 1: the air line stops at the deck
Defect 1: the air line stops at the roof deck. BSC's problem parapet has no air control in either the roof or the wall assembly.
BSC says such a parapet shows air leakage into and out of everything and everywhere.
Two schematic parapet sections. Incorrect: the air line has a visible break at the deck, there is no membrane under the coping, the coping top is flat and the insulation stops at the corner. Correct: all lines run unbroken under a coping that slopes toward the roof. Four numbered points mark the same places in each.
- 1
- The air line: broken at the roof deck on the left, continuous on the right
- 2
- The water line: no membrane under the coping on the left, a membrane under it on the right
- 3
- The coping top: flat on the left, sloped toward the roof on the right
- 4
- The insulation: stops short of the parapet on the left, continues up and over on the right
Sources
- Insight 050: Parapets - Where Roofs Meet Walls (June 2011, rev. 04/2012) - Building Science Corporation (Joseph Lstiburek)